<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-24 22-21-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 70 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 2.9 kHz -69 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19060 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-2,4 dBr 1,43 dBr 3,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Stabat Mater (Pa "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/02/24 22.20.25 Total samples: 19060 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,3 dBr MIN: -2,4 dBr AVE: 1,43 dBr % above 12,2 dBr: 0,0 Last value: 0,9 dBr (2025/02/24 22.20.24) 22.06 22.08 22.10 22.12 22.14 22.16 22.18 22.20 -2 0 2 4 Pm [dBr]